FEATURES
Display: 2 vacuum fluorescent graphical displays, 16x140 pixels
Memories: 100 sequences of 100 registers plus system memories
Sweep Features: Linear, octave, and decade of up to 10,000 points
Scanner Mode: Allows scanning through a sequence of 100 stores
SINAD Meter: Displays reading from -30dB to 0dB of SINAD
Freq. Counter: Measures frequency error to 1 Hz in three counter modes
Battery Meter: Displays charge left in batteries
Reverse Protection: Generator output protected, switches into 100W internal
load and automatically displays power in dBm or watts.
Power Meter: Displays power from +23dBm to +50dBm, ± .5dB
(200mW-100W)
Attenuator Output: -30dB sample port from load for external equipment
RSSI Meter: 80dB of range on receiver side, -40dBm to -120dBm
Warranty: One-year parts and labor with extended Ramsey Technical
Support and dedicated COM3010 user forum access
GENERATE MODE
Frequency: 100kHz to 1.0GHz in 1Hz steps
Freq. Accuracy: ± 0.1ppm standard
RF Output Level: -140dBm to 0dBm in 0.1dBm steps
Level Accuracy: ± 1dB, 500kHz to 1GHz, ±2dB 100kHz to 500kHz
Units: dBm, uV, mV
Leakage: Better than 1uV, 2 turn loop, 1" diameter at 1”
Spurious Harmonics: -30dBc typical
Non-harmonics: -50dBc typical
FM Modulation: ±75kHz max in 0.1Hz steps
FM Bandwidth: 0.1Hz - 75kHz
Accuracy: ± 0.1ppm (inherently tied to reference frequency)
AM Modulation: 0 - 75% in 1% steps to -100dBm, 0-50% to -140dBm
AM Bandwidth: 10Hz - 10kHz
Accuracy: ± 5%
Distortion: Less than 5%
Modulation Internal: 0.1Hz - 3kHz
Modulation External: 0.1Hz - 3kHz digital and analog selectable, auto leveling.
CTS Encode: 0.1Hz to 999.9Hz at ±.75kHz default deviation, variable
from .1Hz to 2kHz deviation
DPL Encode: ±750Hz, all supported codes
RECEIVE MODE
Frequency: 100kHz to 1.0GHz in 10Hz steps
Sensitivity: Less than 2uV below 512MHz
Less than 3uV above 512MHz
FM Demod: 0 - 6kHz, 0 - 4kHz
AM Demod: 0-100%
CTS Decode: In AF frequency count
Frequency Error: 0-1MHz, two methods of bargraph and count
AF Demod output: 1Vp-p for 6kHz deviation
Gates: 0.1 sec, 1 sec
FREQUENCY COUNTER
Frequency Range: 100kHz - 1GHz
Low Band Sensitivity: Less than 10mV under 70MHz, 1Hz and 10Hz
resolutions
High Band Sensitivity: Less than 10mV, 70MHz - 1GHz, 10Hz and 100Hz
resolutions with divide by ten prescaler
IF Frequency: Receiver sensitivity, range limited to bandwidth of current
set receiver frequency ±10kHz, 1Hz, and 10Hz resolutions
AUDIO COUNTER
Frequency Range: 60Hz - 3000Hz
Gates: 10 Sec variable gate for 1 sec quick updates
Sensitivity: 35mV at demod audio, (± 750Hz deviation)
GENERAL
Receiver input: Has diode protection and fused components
Controls: Elastomeric keypad
Dummy Load: 100W 30dB feed-through attenuator with sample port on
rear, 25% duty cycle full power
RS232 Control: Serial interface provides external function control and
automated calibration
Primary power: 100-240VAC, .6A, 50/60Hz; built in Li-Ion battery
Stand: Professional swivel lock handle/stand
Case Color: Mist gray epoxy powder coat
Supplied Accessories: 110VAC EIA cord, BNC-BNC test cable, whip antenna, one
BP3010 Li-Ion battery
Dimensions: 6” H x 11.9375” W x 14.75” D (152.4mm H x 303.31mm
W x 374.65mm D)
Weight: 14 lbs (6.5kg)
HAND HELD SCOPE OPTION
Max Sample Rate: 10MHz (2MHz single shot)
Max Input Bandwidth: 2MHz (-3dB at 50mV, 1V & 20V/Div x 1 setting)
Input Impedance: 1M ohm, 20pf standard scope probes
Input Coupling: DC, AC, and ground (zero reference)
Vert Resolution: 8 bit, ±1 bit linearity
Trigger Modes: Run, normal, once, roll mode for 1s/div and
slower timebase
LCD Graphics: 64 x 128 pixel, white backlit
Signal Storage: 256 samples with 2 memories, max 125 visible
samples, 256 using X shift
dBm Measurement: -73dB to +40dB, ±0.5dB accuracy
(0dBm=0.775V at 600 ohm)
dBV Measurement: -75dB to +38dB, ±0.5dB accuracy
(0dBV=1V)
True RMS Measurement: .1mV to 80V, ±2.5% accuracy
P/P AC Range: 0.1mV to 160V, ±2.0% accuracy
Timebase Ranges: 0.2us to 1hr/div, 32 steps
Input Sensitivity Range: 5mV to 20V/div at time 1, 50mV to 200V/div
at times 10, 12 steps
Probe Calibration Output: 2KHz/5Vpp approx
Power Requirement: 9V, 500mA adapter provided
Batteries: (not included) 5 AA Alkaline batteries
or 5 AA NiMH rechargable batteries
Battery Life: Up to 20 hours with AA Alkaline
Operating Temperature: 0° to 50° C (32° to 122° F)
Dimensions: 4.13” x 7.95” x 1.38” (105mm x 220mm x 35mm)
Weight: 14 oz (395g) less batteries
Accessories Provided: Foam lined carrying case, COM3010 interface cable,
standard scope probes, AC power supply, user’s manual
Optional Accessories: BP3010 Additional Li-Ion battery pack (max 3)
CC3010 Black padded Cordura carrying case
DETAILED SPECIFICATIONS
3
COM3010 Full Duplex Communications Service Monitor, 100kHz - 1.0GHz, with One 1-Hour Li-Ion Battery Pack $3995.00
BP3010 Additional Li-Ion Battery Pack, Extends Battery Operation By One Hour (Maximum 3 Packs) $59.95
CC3010 Matching Black Padded Cordura Carrying Case With Strap $129.95