46
TYPICAL TEST PROCEDURES
3.20.05 Two-Tone Paging
This function allows the COM3010 user to open the squelch of a receiver using the Two-Tone
Paging format.
1. Connect a whip antenna on the generator RF OUT of the COM3010.
2. Set Generate frequency. Example
3. Enter desired RF Level. Example: 4 V Press
4. Press to access the Two Tone Paging Mode.
5. Use the button to access Tone 1 frequency (0.1Hz to 3 kHz).
6. Set Tone One, Example: 378.6 Hz
7. Use the button to access Tone 2 frequency (0.1Hz to 3 kHz).
8. Set Tone Two, Example: 445.7 Hz Press
9. The deviation is set to a default of 4 kHz. To change the deviation press the
button. Enter in a new deviation value. Example: 3.5 kHz, press
10. Press to access the tone type; select between the four types by using the
arrows. See the chart Below.
11. Press to send the test page.
PAGING MODE T1 LENGTH T2 LENGTH SQUELCH WAIT TIME
Tone Only 0.4 seconds 0.8 seconds 1.3 seconds
Tone/Voice 1.0 second 3.0 seconds 1.3 seconds
Battery Save 2.7 seconds 0.8 second 1.3 seconds
Group Call Not Sent 8.0 seconds 1.3 seconds
Comentarios a estos manuales