Get Commands
Command details
G EL Get elevation
Explanation: Gets the current elevation in the current units with offset added.
Example:
G EL<CR> sent
1203.5ft<CR><LF> returned
G PR Get Pressure
Explanation: Gets the current air pressure in the current units with offset
added.
Example:
G PR<CR> sent
1003.5213Pa<CR><LF> returned
G OP Get Offset Pressure.
Explanation: Gets the offset that is added to the air pressure readings in the
current units.
Example:
G OP<CR> sent
1.5200Pa<CR><LF> returned
G OE Get Offset Elevation.
Command: Description:
G EL
Get elevation
G PR
Get pressure
G OP
Get offset pressure
G OE
Set offset elevation
G VB
Get supply voltage
G CH
Get entire chart (in CSV format)
G PS
Get pressure stats (in CSV format)
G ES
Get elevation stats (in CSV format)
G PU
Get Pressure Units and index
G EU
Get Elevation Units and index
G SR
Get Sample Rate and index
G SD
Get Screen dump